Skip to main content

An insight on achieving low phosphorus and low iron on a trickling filter works: PRESENTATION ONLY

Mariana Pinheiro, Process Design Engineer, Southern Water, UK

(Free)

Download now


The brief

Upgrade the works as required to meet the new Total Phosphorus (TP) permit of 0.25 mg/l as a rolling 12 months mean whilst maintaining compliance with the other permit determinands.

In reality TP permit will drive the TSS limit to ~ 3 mg/l

The Old Works

– Conventional trickling filter (TF) works with single point ferric dosing
– Ferric mixing achieved by running the recirculation constantly to the PST distribution chamber
– Ferric and recirculation both inhibited in storm conditions
– Pyramidal PSTs with adequate capacity- Adequate biological capacity for permit
– Pyramidal HSTs marginally short of capacity at peak flows

Download now

Please fill in your details to download the FREE proceeding.