Tarnów WWTP

• Maximum flowrate: 86,400 m3/day

• Average flowrate: 35,000 – 40,000 m3/day

• Maximum capacity: 460,000 p.e.

• Actual capacity: 330,000-350,000 p.e.

• Mechanical-biological-chemical process

Sludge line at Tarnów WWTP

• Primary and WAS treatment (ratio 1:2)

• Final sludge cake: 32-36%DS

• Final DS. after drying (3-level belt dryer):

  • 40-45%DS in continuous mode
  • >95%DS in batch mode
  • biosolids used for land reclamation